Standard Test Method for External Pressure Resistance of “Fiberglass”<brk /> (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe
“玻璃纤维”<brk/>(玻璃纤维增强热固性树脂)管外部耐压性的标准试验方法
1.1
This test method covers determination of the resistance of fiberglass pipe to external pressure. It classifies failures as buckling, compressive, and leaking. Both glass-fiber-reinforced thermosetting-resin pipe (RTRP) and glass-fiber-reinforced polymer mortar pipe (RPMP) are fiberglass pipes.
Note 1:
For the purposes of this standard, polymer does not include natural polymers.
1.2
The values stated in inch-pound units are to be regarded as standard. The SI units given in parentheses are for information only.
Note 2:
There is no known ISO equivalent to this standard.
1.3
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
====== Significance And Use ======
5.1
The values obtained by this test method are applicable only to conditions that specifically duplicate the procedures used.
5.2
After a scaling constant is determined for one diameter, this may be used for calculating the external failure pressures of other diameters as long as the resin and reinforcement (if used), the wall thickness-to-diameter ratio, and the reinforcement pattern (if reinforcement is used) are the same.
Note 3:
Based upon tests conducted on one size of pipe, a scaling constant is calculated according to
10.1
or
10.2
. The appropriate constant is used to calculate failure pressure for other pipe diameters, but it can only be applied if the same resin and reinforcement are used, the wall thickness to diameter ratios are similar, and the reinforcement pattern is constant.
5.3
In the application of the following test requirements and recommendations, care must be exercised to ensure that the specimens tested are truly representative of the group being studied.