1.1
These test methods cover the measurement of the adherence of the release liner to the adhesive of a pressure-sensitive adhesive label.
1.2
These test methods provide means of assessing the uniformity of the adhesion to the liner of a given type of pressure-sensitive label. The assessment may be within a sheet or roll between sheets or rolls or between production lots.
1.3
Variation in the label backing, liner, liner release coating, adhesive, and adhesive coating weight, affect the response. Therefore, these methods cannot be used to pinpoint the specific cause(s) of nonuniformity.
1.4
These test methods may not be appropriate to test labels having either relatively stiff backings or stiff liners, or backings showing high stretch at low forces. These characteristics will result in a high variability of the test response that is not a true indication of the real nature of the adhesive bond.
1.5
The values stated in either SI or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently, without combining values in any way.
1.6
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
====== Significance And Use ======
5.1
These test methods are a tool for development and quality assurance use. Given a specific pressure-sensitive label and liner and a requirement in terms of the minimum for maximum peel value expected for this liner removal from the label, the data from the test can be used in conjunction with acceptance criteria.