1.1
This guide covers techniques that can be used to calibrate a groundwater flow model. The calibration of a model is the process of matching historical data, and is usually a prerequisite for making predictions with the model.
1.2
Calibration is one of the stages of applying a groundwater modeling code to a site-specific problem (see Guide
D5447
). Calibration is the process of refining the model representation of the hydrogeologic framework, hydraulic properties, and boundary conditions to achieve a desired degree of correspondence between the model simulations and observations of the groundwater flow system.
1.3
Flow models are usually calibrated using either the manual (trial-and-error) method or an automated (inverse) method. This guide presents some techniques for calibrating a flow model using either method.
1.4
This guide is written for calibrating saturated porous medium (continuum) groundwater flow models. However, these techniques, suitably modified, could be applied to other types of related groundwater models, such as multi-phase models, non-continuum (karst or fracture flow) models, or mass transport models.
1.5
Guide
D5447
presents the steps to be taken in applying a groundwater modeling code to a site-specific problem. Calibration is one of those steps. Other standards have been prepared on environmental modeling, such as Guides
D5490
,
D5609
,
D5610
,
D5611
,
D5718
, and Practice
E978
.
1.6
Units—
The values stated in either SI units or inch-pound units (given in brackets) are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.7
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8
This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a project's many unique aspects. The word “Standard” in the title of this document means only that the document has been approved through the ASTM consensus process.
1.9
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
====== Significance And Use ======
5.1
Most site-specific groundwater flow models must be calibrated prior to use in predictions. In these cases, calibration is a necessary, but not sufficient, condition which must be obtained to have confidence in the model's predictions.
5.2
Often, during calibration, it becomes apparent that there are no realistic values of the hydraulic properties of the soil or rock which will allow the model to reproduce the calibration targets. In these cases the conceptual model of the site may need to be revisited or the construction of the model may need to be revised. In addition, the source and quality of the data used to establish the calibration targets may need to be reexamined. For example, the modeling process can sometimes identify a previously undetected surveying error, which would results in inaccurate hydraulic head targets.
5.3
This guide is not meant to be an inflexible description of techniques for calibrating a groundwater flow model; other techniques may be applied as appropriate and, after due consideration, some of the techniques herein may be omitted, altered, or enhanced.
Note 1:
Users of the inverse method should be aware that the method may have several solutions, all equally well calibrated.
(
1
)
4