1.1 This specification sets forth the requirements for duplex, types E, J, K, N and T thermocouple wire, insulated with E-glass, S-glass, amorphous silica fiber or polycrystalline fiber.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.3
This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
====== Significance And Use ======
4.1 This specification presents the requirements for impregnated and non-impregnated fiber insulated thermocouple wire for normally accepted industrial use, but does not attempt to define such usage.
4.2 A supplement contains the requirements for insulated thermocouple wire that will be exposed to high humidity. The purchase order or inquiry shall specify if this supplement is required.