Standard Test Method for Ethylene, Other Hydrocarbons, and Carbon Dioxide in High-Purity Ethylene by Gas Chromatography
通过气相色谱法测定高纯度乙烯中乙烯 其他碳氢化合物和二氧化碳的标准试验方法
1.1 This test method covers the determination of carbon dioxide, methane, ethane, acetylene, and other hydrocarbons in high-purity ethylene. Hydrogen, nitrogen, oxygen, and carbon monoxide are determined in accordance with Test Method D2504. The percent ethylene is obtained by subtracting the sum of the percentages of the hydrocarbon and nonhydrocarbon impurities from 100. The method is applicable over the range of impurities from 1 to 500 parts per million volume (ppmV).
1.2
This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
For some specific hazard statements, see Section 6.
1.3 The values stated in acceptable metric units are to be regarded as the standard. The values in parentheses are for information only.
====== Significance And Use ======
High-purity ethylene is required as a feedstock for some manufacturing processes, and the presence of trace amounts of carbon dioxide and some hydrocarbons can have deleterious effects. This method is suitable for setting specifications, for use as an internal quality control tool and for use in development or research work.