Standard Practice for Quality Systems for Conducting In Situ Measurements of Lead Content in Paint or Other Coatings Using Field-Portable X-Ray Fluorescence (XRF) Devices
使用现场便携式X射线荧光(XRF)装置进行涂料或其他涂层中铅含量现场测量的质量体系的标准实施规程
1.1
This practice covers the collection and documentation of quality control (QC) measurements for determining acceptable levels of instrumental performance when using field-portable energy-dispersive X-ray fluorescence spectrometry devices (XRFs) for the purposes of generating lead classification results from measurements on paint and other coating films within buildings and related structures.
1.1.1
This practice is not designed to determine the presence of a hazard as defined by authorities having jurisdiction in the United States or other jurisdictions. See Guide
E2115
and the HUD Guidelines for more information.
1.2
QC procedures covered in this provisional practice include the performance of calibration checks, substrate bias checks, and specific instructions for documenting the collected data for later use in reporting the results.
1.3
No detailed operating instructions are provided because of differences among the various makes and models of suitable instruments. Instead, the analyst is to follow the instructions provided by the manufacturer of the particular XRF device or other relevant sources of information on XRF operation.
1.4
This practice contains notes which are explanatory and are not part of the mandatory requirements of this provisional practice.
1.5
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
====== Significance And Use ======
5.1
This practice provides procedures to generate and document QC data for ensuring that an XRF is operating within acceptable tolerances throughout the testing period when being used to collect lead results during a lead-based paint (LBP) inspection for the purposes of generating lead classification results.
5.2
This practice is intended to supplement XRF instrument manufacturer protocols and PCSs
4
through the use of QA and QC procedures to provide uniform lead testing practices among the wide variety of available field-portable XRF instruments.
Note 1:
The United States requires that an XRF used to perform a lead-based paint inspection in housing is to be utilized according to the PCS for the particular instrument model in use.
5.3
While the QC results collected using this practice can provide assurances that an XRF instrument is operating within acceptable tolerances, this practice does not determine an actual level of confidence for a classification result obtained from an XRF measurement.
5.4
This practice does not address selection of test locations or representative sampling for leaded paint. Additional information on conducting measurements of lead in leaded paint or other coatings may be found in Guide
E2115
and the HUD Guidelines, Chapter 7.
5.5
This practice involves the use of field-portable XRF instruments that may contain radioactive materials or X-ray tubes that emit X-rays or gamma rays, or both. These instruments are intended for use only by qualified, trained personnel.
5.6
The use of field-portable XRF instruments for measurement of lead may not accurately reveal low but still potentially hazardous levels of lead.