Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Vector measurement-based systems (Frequency range of 600 MHz to 6 GHz)
手持式和车载无线通信设备射频场对人体特定吸收率评估的测量程序
This part of IEC 62209 specifies measurement protocols and test procedures for the reproducible measurement of peak spatial-average specific absorption rate (psSAR) induced inside a simplified model of a human head or body by radio-frequency (RF) transmitting devices, with a specified measurement uncertainty. Requirements are provided for psSAR assessment using vector measurement-based systems. Such systems determine the psSAR by three-dimensional (3D) field reconstruction within the volume of interest in accordance with the requirements herein for the measurement system, calibration, uncertainty
assessment and validation methods. The protocols and procedures apply for the psSAR assessments covering a significant majority of people including children during use of wireless communication devices operated in close proximity to the head or body.Cross References:ISO/IEC Guide 98-1:2009EN 62209-2:2010IEC TR 62630:2010IEC 62209-2:2010IEC 62479EN 62479GUM:1995ISO/IEC Guide 98-3IEC/IEEE 62704-1IEC 62209-1:2016EN 62209-1:2016IEEE 1720:2012ISO/IEC 17025NIST TN1297:1994ISO/IEC 17043EN ISO/IEC 17043EN ISO/IEC 17025EN ISO 3611:2010ISO 3611:2010All current amendments available at time of purchase are included with the purchase of this document.