Building environment design - Design, dimensioning, installation and control of embedded radiant heating and cooling systems - Part 4: Dimensioning and calculation of the dynamic heating and cooling capacity of Thermo Active Building Systems (TABS) (ISO 11855-4:2012) 建筑环境设计 - 嵌入式辐射加热和冷却系统的设计 尺寸 安装和控制 - 第4部分:热活性建筑系统(TABS)的动态加热和冷却能力的尺寸和计算(ISO 11855-4:2012)
发布日期: 2015-08-05
实施日期: 2015-08-05
ISO 11855-4:2012允许根据热增益计算热活性建筑系统(TABS)的峰值制冷能力,例如太阳能增益,内部热量增加和通风,以及计算水中的冷却功率需求侧面,用于冷却系统的尺寸,关于冷却器尺寸,流体流量等 ISO 11855-4:2012定义了一种旨在计算非稳态条件下的加热和制冷能力的详细方法
ISO 11855-4:2012 allows the calculation of peak cooling capacity of Thermo Active Building Systems (TABS), based on heat gains, such as solar gains, internal heat gains, and ventilation, and the calculation of the cooling power demand on the water side, to be used to size the cooling system, as regards the chiller size, fluid flow rate, etc. ISO 11855-4:2012 defines a detailed method aimed at the calculation of heating and cooling capacity in non-steady state conditions.
分类信息
关联关系
研制信息
归口单位: CEN/TC 228-
相似标准/计划/法规
现行
EN ISO 11855-4-2021
Building environment design - Embedded radiant heating and cooling systems - Part 4: Dimensioning and calculation of the dynamic heating and cooling capacity of Thermo Active Building Systems (TABS) (ISO 11855-4:2021)
建筑环境设计嵌入式辐射加热和冷却系统第4部分:热活性建筑系统(TAB)动态加热和冷却能力的尺寸标注和计算
2021-09-01
现行
FprEN ISO 11855-8
Building environment design - Design, dimensioning, installation and control of embedded radiant heating and cooling systems - Part 8: Electrical heating systems (ISO/FDIS 11855-8:2023)
建筑环境设计嵌入式辐射加热和冷却系统的设计、尺寸、安装和控制第8部分:电加热系统
现行
EN ISO 11855-8-2023
Building environment design - Design, dimensioning, installation and control of embedded radiant heating and cooling systems - Part 8: Electrical heating systems (ISO 11855-8:2023)
建筑环境设计嵌入式辐射加热和冷却系统的设计、尺寸、安装和控制第8部分:电加热系统
2023-12-13
现行
ISO 11855-6-2018
Building environment design — Design, dimensioning, installation and control of embedded radiant heating and cooling systems — Part 6: Control
建筑环境设计 - 嵌入式辐射加热和冷却系统的设计 尺寸 安装和控制 - 第6部分:控制
2018-09-11
现行
DIN EN ISO 11855-4
Building environment design - Embedded radiant heating and cooling systems - Part 4: Dimensioning and calculation of the dynamic heating and cooling capacity of Thermo Active Building Systems (TABS) (ISO 11855-4:2021)
建筑环境设计嵌入式辐射供暖和制冷系统第4部分:热活性建筑系统(TABS)动态加热和冷却能力的尺寸标注和计算;德国版本EN ISO 11855-4:2021
2022-04-01
现行
ISO 11855-4-2021/Amd 1-2023
Building environment design — Embedded radiant heating and cooling systems — Part 4: Dimensioning and calculation of the dynamic heating and cooling capacity of Thermo Active Building Systems (TABS) — Amendment 1
建筑环境设计嵌入式辐射供暖和制冷系统第4部分:热活性建筑系统(TABS)动态供暖和制冷能力的尺寸和计算修改件1