Methods for sampling and analysis of ambient air, Method 9.16: Determination of suspended particulate matter - PM 10 continuous direct mass method using a tapered element oscillating microbalance monitor incorporating a filter dynamic measurement system (FDMS) unit
环境空气取样和分析方法 方法9.16:悬浮颗粒物的测定-使用锥形元件振荡微天平监测器(包括过滤器动态测量系统(FDMS)装置)的PM 10连续直接质量法
Sets out a method for the continuous determination of PM10 particulate matter in ambient air using a tapered element oscillating microbalance (TEOM) monitor incorporating a filter dynamic measurement system (FDMS) unit.