现行 EN 81-72:2020
到馆阅读
收藏跟踪
购买正版
Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts 电梯的安装和安装的安全规定 - 乘客和货物乘客电梯的特殊应用 - 第72部分:消防员升降机
发布日期: 2020-07-22
实施日期: 2020-07-22
1.1本文件规定了EN 81-20:2020对可用于消防和疏散目的的新型客货两用电梯的附加或偏离要求 在消防员的控制下。 1.2当满足以下条件时,本文件适用: -电梯井和电梯环境的设计旨在限制火灾的进入, 电梯井、机舱和安全区域的热量和烟雾; -建筑设计限制了进入电梯井的水流; -消防电梯不作为逃生通道; -电梯井及电梯环境防火等级至少与建筑结构相同; -电源安全可靠; -电缆 向电梯供电的防火等级与电梯井结构的防火等级相同; -实施适当的维护和验证计划。 1.3这个 文件不包括: -使用带有部分封闭井的电梯作为消防电梯; -安装在新建筑物或现有建筑物内的电梯,不包括在耐火范围内 建筑结构; -对现有电梯进行重要改造。 1.4本文件未定义: -消防电梯的数量和消防操作期间需要服务的楼层; -安全区域的大小; -在多层电梯的最高层以外的地方进行消防作业。 1.5本文件涉及重大危险、危险情况 以及与消防电梯相关的事件(如第4条所列),当消防电梯按计划使用时,以及在安装人员预见的条件下。 1.6以下重大危害 本文件未涉及,假定由建筑设计师解决: -没有足够的或位置正确的消防电梯来移动消防队员 建筑; -消防人员电梯井、安全区域、机械空间或汽车发生火灾; -任何楼层均无楼层识别标志; -水管理系统不运行 正确地。
1.1 This document specifies the additional or deviating requirements to EN 81-20:2020 for new passenger and goods passenger lifts, which can be used for firefighting and evacuation purposes under firefighters control. 1.2 This document applies, when the following conditions are fulfilled: - the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas; - the building design limits the flow of water into the lift well; - the firefighters lift is not used as an escape route; - the lift well and the lift environment are fire protected for at least to the same level as the building structure; - the power supply is secure and reliable; - the electrical cable(s) providing power to the lift is fire protected to the same fire protection level as given to the lift well structure; - a suitable maintenance and verification plan is implemented. 1.3 This document does not cover: - the use of lifts with partially enclosed wells for use as firefighters lifts; - lifts installed in new or existing buildings, which are not included in fire resisting building structure; - important modification to existing lifts. 1.4 This document does not define: - the number of firefighters lifts and the floors to be served during firefighting operations; - size of safe area(s); - the use of other than the highest deck of a multi deck lift for firefighting operations. 1.5 This document deals with the significant hazards, hazardous situations and events relevant to firefighters lifts (as listed in Clause 4) when they are used as intended and under the conditions as foreseen by the installer. 1.6 The following significant hazards are not dealt with in this document and are assumed to be addressed by the building designer: - not having enough or correctly located firefighters lifts to move the firefighters up the building; - a fire in the firefighters lift well, safe area, machinery space or car; - the absence of building floor identification signs at any floor; - water management is not operating correctly.
分类信息
关联关系
研制信息
归口单位: CEN/TC 10-
相似标准/计划/法规