购买正版
Standard Practice for Secondary Calibration of Acoustic Emission Sensors 声发射传感器二次校准的标准实践
发布日期: 2020-04-01
1.1 本规程涵盖了声发射(AE)传感器的二次校准要求。二次校准产生传感器对声发射工作中通常遇到的类型波的频率响应。产生用于校准的信号的源安装在与被测传感器(SUT)相同的试块表面上。在这些条件下,瑞利波占主导地位;校准结果主要表示传感器对瑞利波的灵敏度。传感器的灵敏度是在100 kHz到1 MHz的范围内确定的。灵敏度值通常在相隔约10 kHz的频率下确定。 校准单位为每单位机械输入(位移、速度或加速度)的伏特。 1.2 单位- 以国际单位制或英寸-磅单位表示的数值应单独视为标准值。每个系统中规定的值不一定是精确的等价物;因此,为确保符合本标准,每个系统应独立使用,且两个系统的值不得组合。 1.3 本标准并非旨在解决与其使用相关的所有安全问题(如有)。本标准的用户有责任在使用前制定适当的安全、健康和环境实践,并确定监管限制的适用性。 1.4 本国际标准是根据世界贸易组织技术性贸易壁垒(TBT)委员会发布的《关于制定国际标准、指南和建议的原则的决定》中确立的国际公认标准化原则制定的。 ====意义和用途====== 4.1 本规程的目的是使已通过主要校准进行校准的传感器能够将校准转移到其他传感器。
1.1 This practice covers requirements for the secondary calibration of acoustic emission (AE) sensors. The secondary calibration yields the frequency response of a sensor to waves of the type normally encountered in acoustic emission work. The source producing the signal used for the calibration is mounted on the same surface of the test block as the sensor under testing (SUT). Rayleigh waves are dominant under these conditions; the calibration results represent primarily the sensor's sensitivity to Rayleigh waves. The sensitivity of the sensor is determined for excitation within the range of 100 kHz to 1 MHz. Sensitivity values are usually determined at frequencies approximately 10 kHz apart. The units of the calibration are volts per unit of mechanical input (displacement, velocity, or acceleration). 1.2 Units— The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. ====== Significance And Use ====== 4.1 The purpose of this practice is to enable the transfer of calibration from sensors that have been calibrated by primary calibration to other sensors.
分类信息
关联关系
研制信息
归口单位: E07.04
相似标准/计划/法规