1.1
This specification establishes the requirements for seamless copper bus pipe and tube intended for use as electrical conductors.
1.1.1
The product shall be made from one of the following coppers, as denoted in the ordering information:
2
Copper
UNS No.
2
Previously
Used
Designation
Type of Copper
C10100
OFE
Oxygen-free, electronic
C10200
OF
Oxygen-free without residual deoxidants
C10300
—
Oxygen-free, extra low phosphorus
C10400, C10500,
C10700
OFS
Oxygen-free, silver bearing
C11000
ETP
Electrolytic tough pitch
C11300, C11400,
C11600
STP
Silver-bearing tough pitch
C12000
DLP
Phosphorized, low residual phosphorus
1.2
Unless otherwise specified, any one of the above coppers may be furnished.
1.3
Units—
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units, which are provided for information only and are not considered standard.
1.4
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
====== Significance And Use ======
18.1
For purposes of determining compliance with the specified limits for requirements of the properties listed in the following table, an observed value or a calculated value shall be rounded as indicated in accordance with the rounding method of Practice
E29
.
Property
Rounded Unit for Calculated
or Observed Value
Chemical composition
nearest unit in the last right-hand place of figures
of the specified limit
Hardness
Electrical resistivity
nearest unit in the last right-hand place of figures
Electrical conductivity
Tensile strength
nearest ksi (5 MPa)
Elongation: below 5 %
nearest multiple of 0.5 %
5 % and over
nearest 1 %