首页 馆藏资源 舆情信息 标准服务 科研活动 关于我们
现行 IEC 60287-2-3:2024
到馆提醒
收藏跟踪
购买正版
Electric cables - Calculation of the current rating - Part 2-3: Thermal resistance - Cables installed in ventilated tunnels 电缆.额定电流的计算.第2-3部分:热阻.安装在通风隧道中的电缆
发布日期: 2024-06-28
IEC 60287-2-3:20 24作为IEC 60287-2-3:20 24 RLV提供,其中包含国际标准及其红线版本,显示了与上一版本相比技术内容的所有变化。IEC 60287-2-3:20 24描述了一种计算安装在通风隧道中的所有电压电缆的连续额定电流系数的方法。该方法适用于任何类型的电缆。该方法适用于自然通风和强制通风。假设电缆内和隧道周围的纵向热传递可以忽略不计。假设隧道内的所有电缆都是相同的,并且假设隧道横截面不随沿隧道的距离而变化。
IEC 60287-2-3:2024 is available as IEC 60287-2-3:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60287-2-3:2024 describes a method for calculating the continuous current rating factor for cables of all voltages installed in ventilated tunnels. The method is applicable to any type of cable. The method applies to natural as well as forced ventilation. Longitudinal heat transfer within the cables and the surroundings of the tunnel is assumed to be negligible. All cables are assumed to be identical within the tunnel and it is assumed that the tunnel cross-section does not change with distance along the tunnel.
分类信息
关联关系
研制信息
归口单位: TC 20
相似标准/计划/法规
现行
IEC 60287-2-3-2024 RLV
Electric cables - Calculation of the current rating - Part 2-3: Thermal resistance - Cables installed in ventilated tunnels
电缆.额定电流的计算.第2-3部分:热阻.安装在通风隧道中的电缆
2024-06-28
现行
IEC 60287-2-1-2023 CMV
Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance
电缆.额定电流的计算.第2-1部分:热阻.热阻的计算
2023-05-22
现行
IEC 60287-2-1-2023
Electric cables - Calculation of the current rating - Part 2-1: Thermal resistance - Calculation of thermal resistance
电缆.额定电流的计算.第2-1部分:热阻.热阻的计算
2023-05-22
现行
KS C IEC 60287-2-1
전기 케이블 — 전류정격 계산 — 제2-1부: 열 저항 — 열 저항 계산
电缆 - 电流额定值的计算第2-1部分:热阻 - 热阻的计算
2019-12-31
现行
KS C IEC 60287-2-1
전기 케이블 — 정격 전류 계산 — 제2-1부: 열 저항 — 열 저항 계산
电缆.额定电流的计算.第2-1部分:热阻.热阻的计算
2022-12-20
现行
GOST R IEC 60287-2-1-2009
Кабели электрические. Расчет номинальной токовой нагрузки. Часть 2-1. Тепловое сопротивление. Расчет теплового сопротивления
电缆 电流额定值的计算 第2-1部分 热阻 计算热阻
现行
IEC 60287-3-2-2012
Electric cables - Calculation of the current rating - Part 3-2: Sections on operating conditions - Economic optimization of power cable size
电缆 - 电流额定值的计算 - 第3-2部分:操作条件部分 - 电源线尺寸的经济优化
2012-07-04
现行
KS C IEC 60287-3-2
전기 케이블 — 정격 전류 계산 —제3-2부: 운전 조건 — 전력케이블 크기의 경제적 최적화
电缆 - 电流额定值的计算 - 第3-2部分:操作条件部分 - 电源线尺寸的经济优化
2020-12-24
现行
GOST R IEC 60287-3-2-2011
Кабели электрические. Расчет номинальной токовой нагрузки. Часть 3-2. Разделы, касающиеся условий эксплуатации. Экономическая оптимизация размера силовых кабелей
电缆 电流额定值的计算 第3-2部分 操作条件部分 电力电缆尺寸经济优化
现行
IEC 60287-1-3-2023 CMV
Electric cables - Calculation of the current rating - Part 1-3: Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses
电缆.额定电流的计算.第1-3部分:额定电流方程(100%负载系数)和损耗的计算.并联单芯电缆之间的均流和循环电流损耗的计算
2023-05-22
现行
KS C IEC 60287-1-3(2019 Confirm)
전기 케이블 — 정격 전류의 계산 — 제1-3부: 정격 전류식(100 % 부하율)과 손실 계산 — 병렬 단심 케이블 상호간의 전류 분담 및 순환 전류 손실의 계산
电缆 - 电流额定值的计算 - 第1-3部分:电流额定方程(100%负载因子)和损耗计算 - 并联单芯电缆之间的电流共享和循环电流损耗的计算
2014-10-03
现行
IEC 60287-1-3-2023
Electric cables - Calculation of the current rating - Part 1-3: Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses
电缆.额定电流的计算.第1-3部分:额定电流方程(100%负载系数)和损耗的计算.并联单芯电缆之间的均流和循环电流损耗的计算
2023-05-22
现行
UNE 21144-1-3-2003
Electric cables - Calculation of the current rating - Part 1-3: Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses.
电缆.额定电流的计算.第1-3部分:额定电流方程式(100%负载系数)和损耗的计算.平行单芯电缆之间的均流和循环电流损耗的计算
2003-09-29
现行
GOST R IEC 60287-1-3-2009
Кабели электрические. Расчет номинальной токовой нагрузки. Часть 1-3. Уравнения для расчета номинальной токовой нагрузки (100 %-ный коэффициент нагрузки) и расчет потерь. Распределение тока между одножильными кабелями, расположенными параллельно, и расчет потерь, обусловленных циркулирующими токами
电缆 电流额定值的计算 第1-3部分 电流额定方程(100%负荷因子)和损失计算 并联单芯电缆之间的电流共享和循环电流损耗的计算
现行
UNE 21144-3-2-2000
Electric cables. Calculation of the current rating. Part 3: Sections on operating conditions. Section 2: Economic optimization of power cable size.
电缆 电流额定值的计算 第3部分:操作条件章节 第2节:电力电缆尺寸的经济优化
2000-12-26
现行
UNE 21144-2-1-1997
ELECTRIC CABLES. CALCULATION OF THE CURRENT RATING. PART 2: THERMAL RESISTANCE. SECTION 1: CALCULATION OF THERMAL RESISTANCE.
电缆 电流额定值的计算 第2部分:热阻 第1节:热阻的计算
1997-05-13
现行
JB/T 10181.11-2014
电缆载流量计算 第11部分:载流量公式(100%负荷因数)和损耗计算一般规定
Electric cables - Calculation of the current rating - Part 11:Current rating equations (100% load factor) and calculation of losses - General
2014-05-06
现行
KS C IEC 60287-3-3(2019 Confirm)
전기 케이블 — 정격 전류의 계산 — 제3-3부: 동작 조건 — 외부 열원과 교차하는 케이블
电缆 - 电流额定值的计算 - 第3-3部分:操作条件部分 - 电缆穿过外部热源
2014-10-03
现行
IEC 60287-3-3-2007
Electric cables - Calculation of the current rating - Part 3-3: Sections on operating conditions - Cables crossing external heat sources
电缆 - 电流额定值的计算 - 第3-3部分:操作条件部分 - 电缆穿过外部热源
2007-05-15
现行
GOST R IEC 60287-3-3-2011
Кабели электрические. Расчет номинальной токовой нагрузки. Часть 3-3. Разделы, касающиеся условий эксплуатации. Кабели, пересекающие внешние источники тепла
电缆 电流额定值的计算 第3-3部分 操作条件部分 电缆穿过外部热源