BS PD CLC/TS 50131-2-9:2016 is applicable to Active Infrared Beam Detectors (AIBDs) installed inside
buildings and used as part of intrusion alarm systems.It specifies four security Grades 1 to 4 (in accordance with EN 50131-1) and uses environmental
Classes I to IV (in accordance with EN 50130-5).This standard covers only AIBDs using interruption based technology. Other technologies i.e. Doppler
based technology are not covered by this document.Functions additional to the mandatory functions specified in this document can be included in the
AIBD, providing they do not adversely influence the correct operation of the mandatory functions.This document does not apply to system interconnections.Cross References:EN 50130-4EN 50130-5EN 50131-1EN 50131-6EN 60404-5IEC 60404-5EN 60404-8-1IEC 60404-8-1EN 60404-14IEC 60404-14EN 50131-2EN 60529IEC 60529All current amendments available at time of purchase are included with the purchase of this document.