Standard Test Method for Color of Maleic Anhydride in the Molten State and After Heating (Platinum-Cobalt Scale) Using Tristimulus Colorimetry
使用三色比色法测定熔融状态和加热后马来酸酐的颜色(铂 - 钴标准)的标准试验方法
1.1
This test method covers an instrumental method for the CIE (Commission International de l’Eclairage) tristimulus measurement of the color of maleic anhydride melt before and after prolonged heating under specified conditions of time and temperature. The measurement is converted to color values in the platinum-cobalt system.
1.2
This test method covers the range 0 to100 Pt-Co color.
1.3
In determining the conformance of the test results using this method to applicable specification, results shall be rounded in accordance with the rounding off methods of Practice
E29
.
1.4
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Sections
7
,
10.3
, and
10.6
.
1.6
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
====== Significance And Use ======
4.1
The color of maleic anhydride can be an indication of the purity of these materials. A high color after heating normally indicates contamination or decomposition.
4.2
This standard is suitable for process quality control and determining if the product meets specifications.