Standard Practice for Testing the Performance of Scanning Raman Spectrometers 扫描拉曼光谱仪性能测试的标准实施规程
发布日期: 2022-12-15
1.1 本规程涵盖扫描拉曼光谱仪性能的常规测试,并在性能下降时帮助定位问题。它也是获取和报告拉曼光谱的指南。 1.2 以国际单位制表示的值应视为标准值。本标准不包括其他测量单位。 1.3 本标准并不旨在解决与其使用相关的所有安全问题(如有)。本标准的使用者有责任在使用前建立适当的安全、健康和环境实践,并确定监管限制的适用性。 有关具体预防措施,请参见 7.2.1 . 1.4 由于使用激光器存在重大危险,因此应结合本规程遵守ANSI Z136.1。 1.5 本国际标准是根据世界贸易组织技术性贸易壁垒(TBT)委员会发布的《国际标准、指南和建议制定原则决定》中确立的国际公认标准化原则制定的。 =====意义和用途====== 4.1 应定期检查扫描拉曼光谱仪,以确定其状况是否足以进行常规测量或是否发生变化。这一做法旨在促进这种确定,如果性能不令人满意,则确定系统中需要注意的部分。这些测试适用于商用单、双或三单色仪扫描拉曼仪器。它们不适用于多通道或傅里叶变换仪器,也不适用于需要脉冲激光源的门控积分器系统。本规程仅适用于经过培训的光学分光镜师,应与标准文本一起使用。
1.1 This practice covers routine testing of scanning Raman spectrometer performance and to assist in locating problems when performance has degraded. It is also intended as a guide for obtaining and reporting Raman spectra. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautions, see 7.2.1 . 1.4 Because of the significant dangers associated with the use of lasers, ANSI Z136.1 should be followed in conjunction with this practice. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. ====== Significance And Use ====== 4.1 A scanning Raman spectrometer should be checked regularly to determine if its condition is adequate for routine measurements or if it has changed. This practice is designed to facilitate that determination and, if performance is unsatisfactory, to identify the part of the system that needs attention. These tests apply for single-, double-, or triple-monochromator scanning Raman instruments commercially available. They do not apply for multichannel or Fourier transform instruments, or for gated integrator systems requiring a pulsed laser source. Use of this practice is intended only for trained optical spectroscopists and should be used in conjunction with standard texts.
分类信息
关联关系
研制信息
归口单位: E13.08
相似标准/计划/法规