Table-top Dry Heat (heated air) Sterilization and Sterility Assurance in Health Care Facilities 医疗设施中的台式干热(热空气)灭菌和无菌保证
本推荐规程为牙医和医生办公室、实验室、门诊诊所和其他医疗机构使用的去污和干热灭菌程序提供了指南。本指南旨在通过确定适用于该灭菌方法的特殊注意事项,并提供关于正确使用台式干热灭菌处理设备的建议,来提高无菌保证。本推荐规程还包括设施设计考虑、人员考虑、工作实践和其他影响无菌保证的变量。
This recommended practice provides guidelines for decontamination and dry heat sterilization procedures used in dentists' and physicians' offices, laboratories, ambulatory care clinics, and other health care facilities. These guidelines are intended to rpomote the assurance of sterility by identifying the special considerations that apply to this method of sterilization and by providing recommendations on the proper use of table-top dry heat sterilization processing equipment. this recommended practice also covers facility desin considerations, personnel considerations, work practices, and other variables that affect sterility assurance.
分类信息
发布单位或类别: 美国-美国牙医协会
关联关系
研制信息
相似标准/计划/法规
现行
AAMI ST40-2004/(R)2018
Periodic review of ANSI/AAMI ST40:2004, Table-top dry heat (heated air) sterilization and sterility assurance in health care facilities (Reaffirmed 2010)
定期审查ANSI/AAMI ST40:2004《医疗设施中的台式干热(加热空气)灭菌和无菌保证》(2010年重申)
2004-10-07
现行
AAMI ST50-2004/(R)2018
Dry Heat (Heated Air) Sterilizers
干热(热空气)灭菌器
2004-04-07
现行
YY 1275-2016
热空气型干热灭菌器
Dry heat (heated air) sterilizers
2016-03-23
现行
CAN/CSA C22.2 NO.61010-2-043-98(R03)
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 2-043: Particular Requirements for Dry Heat Sterilizers Using Either Hot Air or Hot Inert Gas for the Treatment of Medical Materials, and for Laboratory Processes
测量、控制和实验室用电气设备的安全要求.第2-043部分:医疗材料处理和实验室过程中使用热空气或热惰性气体的干热灭菌器的特殊要求
2000-03-21
现行
BS PD IEC TR 61010-3-043-2002
Safety requirements for electrical equipment for measurement, control, and laboratory use-Conformity verification report for IEC 61010-2-043:1997. Particular requirements for dry heat sterilizers using either hot air or hot inert gas for treatment of medical materials and for laboratory processes
测量、控制和实验室用电气设备的安全要求 IEC 61010-2-043:1997的一致性验证报告 医疗材料处理和实验室工艺用热空气或热惰性气体干热灭菌器的详细要求
2002-02-08
现行
DIN EN 61010-2-043
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-043: Particular requirements for dry heat sterilizers using eihter hot air or hot inert gas for the treatment of medical materials and for laboratory processes (IEC 61010-2-043:1997); German version EN 61010-2-043:1997
测量、控制和实验室用电气设备的安全要求.第2-043部分:医疗材料处理和实验室过程中使用热空气或热惰性气体的干热灭菌器的特殊要求(IEC 61010-2-043-1997);德语版
1998-02-01