Rotary tools for threaded fasteners — Performance test method
螺纹紧固件旋转工具 - 性能测试方法
发布日期:
2017-12-06
ISO 5393:2017规定了用于安装螺纹紧固件的电动装配工具(在整个文件中称为“工具”)的实验室性能测试方法。
ISO 5393:2017提供了一种测量扭矩重复性(散射)的方法
-在本文件规定的扭矩率范围内,
-在制造商规定的扭矩调整范围内,以及
-在制造商规定的多个运行周期内。
ISO 5393:2017提供了一种测量内置扭矩测量系统精度的方法,该系统适用于包含此类特征的工具。见附件E。
ISO 5393:
2017给出了关于设备参数、测试内容以及如何评估和展示测试数据的说明。
ISO 5393:2017适用于工具
-任何电源,如气动、液压和电动,包括电池供电,
-以通常连续的方式施加扭矩,以及
-在0.5 Nm至2000 Nm的扭矩范围内。在该范围之外,如果试验报告中记录了修改,则可以修改试验方法。
ISO 5393:2017不适用于
-冲击或脉冲扳手,
-棘轮扳手或带棘轮离合器的扳手,以及
-以不连续增量推进紧固件,克服每次增量静摩擦的其他工具。
ISO 5393:2017允许在任何试验扭矩水平下进行试验;然而,为了尽量减少各种试验扭矩水平所需的试验接头数量,附录a中提供了一份首选试验扭矩水平列表。
ISO 5393:2017 specifies a laboratory performance test method for power assembly tools (referred throughout the document as "tool") for installing threaded fasteners.
ISO 5393:2017 provides a method for the measurement of torque repeatability (scatter)
- over a range of torque rates as specified in this document,
- over a range of torque adjustment as defined by the manufacturer, and
- over a number of operating cycles as defined by the manufacturer.
ISO 5393:2017 provides a method for the measurement of the precision of the built-in torque measurement system for tools incorporating such a feature. See Annex E.
ISO 5393:2017 gives instructions on equipment parameters, what to test for and how to evaluate and present the test data.
ISO 5393:2017 is applicable to tools
- of any power source, e.g. pneumatic, hydraulic, and electric, including battery-powered,
- which apply torque in a generally continuous manner, and
- within the torque range 0,5 Nm to 2 000 Nm. Outside this range, it is acceptable to modify the test method providing that the modification is documented in the test report.
ISO 5393:2017 is not applicable to
- impact or impulse wrenches,
- ratchet wrenches or wrenches with ratcheting clutches, and
- other tools which advance fasteners in discontinuous increments, overcoming static friction at each increment.
ISO 5393:2017 allows a test to be performed at any test torque level; however, in order to minimize the number of test joints necessary for a wide range of test torque levels, a list of preferred test torque levels is provided in Annex A.