IEC 61000-4-12:2017 RLV contains the International Standard and its Redline version. The Redline version is available in English only. The Redline version provides you with a quick and easy way to compare all the changes between this standard and its previous edition. The Redline version is not an official IEC Standard, only the current version of the standard is to be considered the official document.
IEC?61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks.
The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC?61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.
It has the status of a basic EMC publication in accordance with IEC Guide 107.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of a mathematical modelling of ring wave waveform;
b) new Annex B on selection of generators and test levels;
c) new Annex C on explanatory notes;
d) new Annex D on measurement uncertainty;
e) addition of high speed CDN;
f)?addition of a calibration procedure for CDN.