Plastics piping systems for water supply and for buried and above ground drainage, sewerage and irrigation under pressure. Oriented unplasticized poly(vinyl chloride) (PVC-O)-Fitness for purpose of the system
供水、埋地和地上排水、污水和压力灌溉用塑料管道系统 定向未增塑聚氯乙烯(PVC-O) 系统适用性
发布日期:
2019-05-03
范围:EN 17176的本部分规定了定向未增塑材料的适用性特征
供水和埋地排水用聚氯乙烯(PVC-O)实心壁管道系统,
排水系统、经处理的废水和压力下或地面上的灌溉,避免阳光直射。它还规定了本文件中提及的试验方法的试验参数。
注1:本文件不适用于管道系统的现场测试。
与EN 17176-1、EN 17176-2、CEN/TS 17176-3和EN ISO 1452-3一起,适用于PVC-O管道、PVC-O配件及其接头,以及与其他塑料和非塑料材料部件的接头,用于以下用途:
a) 水管和服务线;
b) 建筑物内外的输水;
c) 有压力的排水系统;
d) 在压力下灌溉。
除用途适用性外,其他材料制成的接缝应符合其自身标准
本文件中规定的要求。
适用于最大允许运行压力供水的管道系统
压力(PFA)不超过25巴1)。根据本文件的要求,特别是在输水和除气系统中需要特殊压力和除气负荷的情况下。
对于25摄氏度和45摄氏度之间的温度,EN 17176-2:2019,图C.1适用。
注2:买方或指定方有责任从中做出适当选择
考虑到其特殊要求和任何相关国家法规和安装实践或规范。交叉引用:EN ISO 1452-4CEN/TS 17176-3EN ISO 13845EN ISO 13846ISO 17885EN ISO 1452-3EN ISO 13844EN 17176-1:2019EN 12842:2012EN 17176-2:2019BS EN 17176-2:2019BS EN 17176-1:2019ISO 2531EN ISO 1452-5ISO/TR 4191:2014购买本文件时可提供的所有当前修订版。
Scope: This part of EN 17176 specifies the characteristics of the fitness for purpose of oriented unplasticized
poly(vinyl chloride) (PVC-O) solid wall piping systems intended for water supply and for buried drainage,
sewerage, treated waste water and irrigation under pressure or above-ground where protected from direct sunlight. It also specifies the test parameters for the test methods referred to in this document.
NOTE 1 This document is not intended for on-site testing of pipe systems.
In conjunction with EN 17176-1, EN 17176-2, CEN/TS 17176-3 and EN ISO 1452-3, it is applicable to PVC-O pipes, PVC-O fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following:
a) water mains and services lines;
b) conveyance of water for both outside and inside buildings;
c) drainage and sewerage under pressure;
d) irrigation under pressure.
Joints constructed of other materials shall meet their own standards in addition to the fitness of purpose
requirements specified in this document.
It is applicable to piping systems intended for the supply of water with a maximum allowable operating
pressure (PFA) up to and including 25 bar1). The piping system according to this document is intended for the conveyance of cold water up to and including 45 °C and especially in those applications where special performance requirements are needed, such as impact loads and pressure fluctuations.
For temperatures between 25 °C and 45 °C, EN 17176-2:2019, Figure C.1 applies.
NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these
aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.Cross References:EN ISO 1452-4CEN/TS 17176-3EN ISO 13845EN ISO 13846ISO 17885EN ISO 1452-3EN ISO 13844EN 17176-1:2019EN 12842:2012EN 17176-2:2019BS EN 17176-2:2019BS EN 17176-1:2019ISO 2531EN ISO 1452-5ISO/TR 4191:2014All current amendments available at time of purchase are included with the purchase of this document.