Design of nuclear power plants against seismic events — Part 5: Seismic instrumentation 核电站抗震设计第5部分:地震仪器
发布日期: 2024-10-28
本文件规定了用于检测水冷反应堆核电厂地震事件的仪器的用途和特性。该文件在验证其适用性后也可适用于其他核设施。 本文件不涵盖以下类型的电气系统和设备: -实施IEC 61226定义的核安全功能所涉及的地震仪器,例如自动关闭系统; -地震仪器不涉及IEC 61226定义的核安全功能的实施,但由于例如靠近其他安全分类系统,需要进行硬件鉴定。 根据IEC标准,特别是IEC 61513和较低级别的IEC标准的相关要求,根据安全等级和技术,对此类系统进行指定、设计、制造、鉴定、操作和拆卸用过。 用于实施地震反应堆跳闸系统的地震仪器是根据IEC 63186的要求开发的。 本文档不包括自动停机系统。 本文件规定了地震仪器应满足的要求,以便,首先,可以确定是否超过了工厂步行水平和检查水平所基于的任何设计量,其次,地震时间历史的记录为震后分析提供了必要的输入值。规定了要求,以便独立于检测和记录系统,在时间范围和频率范围内获得公差范围内的可比结果。

This document specifies the utilization and characteristics of instrumentation used to detect seismic events at nuclear power plants with water cooled reactors. The document can also be applied to other nuclear facilities after verifying its applicability.

The following types of electrical systems and equipment are not covered by this document:

     seismic instrumentation involved in the implementation of nuclear safety functions as defined by IEC 61226, for example automatic shutdown systems;

     seismic instrumentation not involved in the implementation of nuclear safety functions as defined by IEC 61226 but which due, for example, to close proximity to other safety classified systems, requires hardware qualification to be performed.

Such systems are specified, designed, manufactured, qualified, operated and dismantled according to the relevant requirements of IEC standards, in particular IEC 61513 and the lower level IEC standards according to the safety class and technologies used.

Seismic instrumentation used for the implementation of seismic reactor trip systems are developed according to the requirements of IEC 63186.

An automatic shutdown system is not covered by this document.

This document specifies the requirements to be fulfilled by the seismic instrumentation such that, firstly, it can be ascertained whether any of the design quantities on which the plant walk-down level and the inspection levels are based have been exceeded and that, secondly, the recording of the time history of the earthquake provides the necessary input values for a post-seismic analysis. The requirements are specified such that, independent of the detection and recording system, comparable results within tolerances are achieved in the time range as well as the frequency range.

分类信息
关联关系
研制信息
归口单位: ISO/TC 85/SC 6
相似标准/计划/法规