Air conditioners and liquid chilling packages with evaporatively cooled condenser and with electrically driven compressors for space cooling - Terms, definitions, test conditions, test methods and requirements 空间制冷用带蒸发冷却冷凝器和电动压缩机的空调器和液体制冷机组.术语、定义、试验条件、试验方法和要求
发布日期: 2022-12-21
实施日期: 2022-12-21
本文件规定了用于空间冷却时,带电动压缩机和蒸发冷却冷凝器的空调器和液体冷却机组性能评定的术语、定义、试验条件、试验方法和要求。蒸发冷却冷凝器通过空气和外部附加水的蒸发进行冷却。这些额外的外部水由特定的供水回路或水箱供水。 本文件不适用于带有冷凝器的空对空和空对水空调,冷凝器由空气和蒸发器上冷凝水的蒸发冷却。 本文件适用于配备水箱或连续供水回路的装置,该装置也可以在不供水的情况下运行。然而,本文件仅涉及这些装置的供水测试。 本文件适用于工厂- 可管道化的制造单元。 本文件适用于工厂制造的固定容量或可变容量机组。 本文件涵盖了成套装置、单分裂和多分裂系统。 对于由多个部件组成的装置,本文件仅适用于作为一个完整包设计和供应的装置。 对于也可以在加热模式下运行的蒸发冷却冷凝器机组,其在该模式下的性能根据FprEN 14511:2022(所有部分)确定。 用于工业过程冷却的装置不在本文件范围内。 本文件规定了性能数据申报的条件,以符合第206/2012号生态设计法规和第626/2011号能源标签法规,即在冷却模式下配备蒸发冷却冷凝器的空调。 注:本文中给出的所有符号均可用于任何语言。
This document specifies the terms, definitions, test conditions, test methods and requirements for rating the performance of air conditioners and liquid chilling packages, with electrically driven compressors and with evaporatively cooled condenser when used for space cooling. The evaporatively cooled condenser is cooled by air and by the evaporation of external additional water. This additional external water is fed by a specific water supply circuit or by a water tank. This document is not applicable to air-to-air and air-to-water air conditioners with a condenser cooled by air and by the evaporation of water condensed on their evaporator. This document is applicable to units equipped with a water tank or with a continuous water circuit supply that can also operate without water feeding. However, this document only concerns the testing of these units with water feeding. This document is applicable to factory-made units which can be ducted. This document is applicable to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by this document. With regard to units consisting of several parts, this document applies only to those designed and supplied as a complete package. For evaporatively cooled condenser units that can also operate in heating mode, their performance in this mode is determined according to EN 14511:2022 (all parts). Units used for industrial processes cooling are not within the scope of this document. This document specifies the conditions for which performance data will be declared for compliance with the Ecodesign Regulation 206/2012 and with the Energy Labelling Regulation 626/2011 of air conditioners with evaporatively cooled condenser in cooling mode. NOTE All the symbols given in this text can be used regardless of language.
分类信息
关联关系
研制信息
归口单位: CEN/TC 113
相似标准/计划/法规