Water quality. Determination of fluoride using flow analysis (FIA and CFA)-Method using flow injection analysis (FIA) and spectrometric detection after off-line distillation
水质 使用流动分析(FIA和CFA)测定氟化物
BS PD ISO/TS 17951-1:2016 specifies a method for the determination of fluoride in waters, waste waters and
effluents by flow injection analysis (FIA). Any insoluble or complexed fluoride is converted to fluoride
ion by a manual distillation procedure from sulfuric/phosphoric acid. Fluoride ion in the distillate is
measured using flow analysis with lanthanum alizarin complexone and spectrometric detection. This
method is applicable to industrial waste waters, effluents, surface waters, ground waters, leachates.
It is not recommended for drinking waters where a distillation step is not required. In this part of
ISO 17951, two working ranges are described:working range I: 0,1 mg/l to 1 mg/l;working range II: 1 mg/l to 10 mg/l.The specification of the calibration solutions are to be adapted accordingly.Cross References:ISO 3696ISO 6353-2ISO 8466-1ISO 8466-2ISO 5667-3ISO 5725-2JIS K 0170-6:2011All current amendments available at time of purchase are included with the purchase of this document.