AC and/or DC-supplied electronic controlgear for discharge lamps (excluding fluorescent lamps). Performance requirements for low frequency squarewave operation
交流和/或直流供电的放电灯电子控制装置(荧光灯除外) 低频方波工作的性能要求
BS EN 62811:2015 specifies performance requirements for electronic controlgear for
use on a.c. and/or d.c. supplies up to 1 000 V and/or a.c. supplies up to 1 000 V at 50 Hz or
60 Hz, associated with discharge lamps, as specified in IEC 61167, which have information
for low frequency square wave operation, where the frequency range of the low frequency is
from 70 Hz to 400 Hz.Tests in this standard are type tests. Requirements for testing individual controlgear during
production are not included.There are regional standards regarding the regulation of mains current harmonics and
immunity for end products like luminaires and independent controlgear. In a luminaire, the
controlgear is dominant in this respect. Controlgear, together with other components, should
comply with these standards.Cross References:IEC 60050IEC 61000-4-14:1999IEC 61000-4-14:1999/A1:2001IEC 61000-4-14:1999/A2:2009EN 61000-4-14:1999EN 61000-4-14:1999/A1:2001EN 61000-4-14:1999/A2:2009IEC 61167IEC 61347-1EN 61347-1IEC 61347-2-12IEC 62386EN 62386IEC 61000-3-2:2000EN 61000-3-2:2000IEC 61000-4-30:2003EN 61000-4-30:2003IEC 61547EN 61547IEC 60410:1973ITU-T Recommendation Z.100:2002All current amendments available at time of purchase are included with the purchase of this document.