Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware-Fire resistance for operable fabric curtains
门、百叶窗和可开启窗户组件(包括其建筑五金元件)耐火和/或防烟试验结果的扩展应用 可操作织物窗帘的耐火性
BS EN 15269-11:2018 covers vertically mounted types of manual or powered, operable fabric curtain
assemblies with downward closing operation. Curtain systems are different from (are separated from)
door systems due to their not rigid closure element typically made of thin walled materials as for
instance woven or knitted fabrics and foils. These closure elements are not able to carry significant
loads normal to their surface by their bending stiffness. In other words: curtain systems are separated
from door systems because they can only conduct pulling forces by tensile stress in plane to their
surface. Pushing forces are not conducted in plane to their surface.Cross References:EN 13501-2EN 1993-1-2EN 1363-1EN 13501-2EN 15269-1EN 1634-1EN 1993-1-2EN 15269-1EN 1634-1EN 1363-1ISO 13943EN ISO 13943EN 16035EN 15254-4EN 16034EN 15254-4EN 15725All current amendments available at time of purchase are included with the purchase of this document.