Connectors for electrical and electronic equipment. Product requirements-Rectangular connectors. Detail specification for 10-way, shielded, free and fixed connectors for I/O and data transmission with frequencies up to 500 MHz
电气和电子设备用连接器 产品要求
Scope: This part of IEC 61076 covers 10-way, shielded, free and fixed rectangular connectors for data
transmission with frequencies up to 500 MHz and specifies the common dimensions, mechanical, electrical and transmission characteristics and environmental requirements as well as test specifications respectively.
Connectors covered in this document are provided in three codings that differ only for the position of the polarization key and keyway, in view of their differently intended use:* Connectors Type A and C are intended for 10/100 Mbit/s as well as for 1/ 2,5 / 5 /10 Gbit/s Ethernet communication.* Connectors Type B are intended for all other non-Ethernet applications such as signalling, serial or other industrial bus communication systems.
A-coding: The 45° cut corner used as polarization key and keyway system is located on the lower left corner of the male fixed connector (viewed from mating face) (Figures 5a, 5b).
B-coding: The 45° cut corner is located on the upper left corner of the male fixed connector (Figures 5c, 5d).
C-coding: There are two 45° corners located at the upper left and lower left corner (Figures 5e, 5f).
In this document, the three codings, A, B, and C are designated as "Type A", "Type B" and "Type C".Cross References:IEC 60512-11-10IEC 60512-9-1IEC 60512-15-6IEC 60512-2-5IEC 60512-11-4IEC 60068-2-38IEC 60512-6-3IEC 60512-6-4IEC 60512-11-7IEC 60512-5-2IEC 60512-11-9IEC 60050-581IEC 60512-25-7IEC 60512-27-100IEC 60352 (all parts)IEC 60512-1-2IEC 60512-2-1IEC 60512-11-3IEC 60512-4-1IEC 60664-1IEC 60512-13-5IEC 60068-1IEC 60512-1-1IEC 60512-1IEC 60512-13-2IEC 60512-3-1IEC 60603-7:2008IEC 61076-1:2006IEC 61076-3:2008All current amendments available at time of purchase are included with the purchase of this document.