Standard Test Method for Gravimetric Determination of Nonvolatile Residue (NVR) in Environmentally Controlled Areas for Spacecraft
航天器环境控制区非挥发性残留物(NVR)的重量测定标准试验方法
1.1
This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft.
1.2
The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is left to the user to infer the relationship between the NVR found on the sampling plate surface and that found on any other surfaces.
1.3
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4
The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
====== Significance And Use ======
5.1
The NVR determined by this test method is that amount that can reasonably be expected to exist on hardware exposed in environmentally controlled areas.
5.2
The evaporation of the solvent at or near room temperature is to quantify the NVR that exists at room temperature.
5.3
Numerous other methods are being used to determine NVR. This test method is not intended to replace methods used for other applications.