Nanomanufacturing. Key control characteristics-Nano-enabled metal-oxide interfacial devices. Test method for the polarization properties by thermally stimulated depolarization current
纳米制造 关键控制特性
There are two types of thermally stimulated current (TSC) measurement methods, classified by
the origin of the current. One is generated by the detrapping of charges. The other one is
generated by depolarization. The latter is frequently called thermally stimulated depolarization
current (TSDC). This part of IEC 62607 focuses on the latter method, and specifies the
measurement procedures to be developed for determining polarization properties of metal-oxide
interfacial devices.All current amendments available at time of purchase are included with the purchase of this document.