1.1
This specification covers the requirements for seamless copper tube intended for use in the connection, repairs, or alternations of air conditioning or refrigeration units in the field.
Note 1:
Fittings used for soldered or brazed connections in air conditioning and refrigeration systems are described in ASME Standard B16.22.
Note 2:
The assembly of copper tubular systems by soldering is described in Practice
B828
.
Note 3:
Solders for joining copper tubular systems are described in Specification
B32
. The requirements for acceptable fluxes for these systems are described in Specification
B813
.
1.2
The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified:
Copper
UNS No.
Previously Used
Designation
Description
C10200
OF
Oxygen free without
residual deoxidants
C12000
DLP
Phosphorus deoxidized,
low residual phosphorus
C12200
DHP
Phosphorus deoxidized,
high residual phosphorus
1.3
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4
The following hazard statement pertains only to the test method described in
18.2.4
of this specification:
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.