1.1 This test method
2
covers the detection of hydrogen sulfide in liquefied petroleum (LP) gases. The sensitivity of the test is about 4 mg/m
3
(0.15 to 0.2 grain of hydrogen sulfide per 100 ft
3
) of gas.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.3
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
====== Significance And Use ======
4.1 Liquefied petroleum gases and their products of combustion must not be unduly corrosive to the materials with which they come in contact. The potential personnel exposure hazards of H
2
S also make the detection and measurement of hydrogen sulfide important, even in low concentrations. In addition, in some cases the odor of the gases must not be objectionable. (See Specification
D1835
and GPA 2140
.)