Cable networks for television signals, sound signals and interactive services - Part 7-3: Hybrid fibre coax outside plant status monitoring - Power supply to transponder interface bus (PSTIB)
电视信号、声音信号和交互服务用电缆网络.第7-3部分:混合光纤同轴电缆厂外状态监测.转发器接口总线(PSTIB)的电源
IEC 60728-7-3:2009 specifies requirements for the Hybrid Fibre Coax (HFC) Outside Plant (OSP) Power Supplies (PS). This standard is part of a series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The purpose of the standards is to support the design and implementation of interoperable management systems for evolving HFC cable networks. The Power Supply to Transponder Interface Bus (PSTIB) specification describes the physical (PHY) interface and related messaging and protocols implemented at the Data Link Layer (DLL), layers 1 and 2 respectively in the 7-layer ISO-OSI reference model, that support communications between compliant transponders and the managed OSP power supplies and other related power equipment to which they interface. It constitutes a technical revision and includes the following significant technical changes with respect to the previous edition: All changes from standard ANSI/SCTE 25-3 v1.0 to standard ANSI/SCTE 25-3 v1.1 (2005) have been taken into account in this second edition. Clause 7 is based on standard ANSI/SCTE 110 (2005). Addition of informative Annex A concerning hybrid management sub-layer.