Dynamics and Control of a Chilled Water Coil 冷冻水盘管的动力学与控制
利用系统辨识技术建立了冷水盘管的经验模型。线圈模型用于开发直接数字控制器的仿真,以通过P、PI和PID控制算法预测系统对输入的响应。测量了实际冷冻水盘管的响应,并将其与模型的预测响应进行了比较。发现该模型可有效预测每种控制算法的不同增益值的响应。当使用该模型时,发现一组增益对系统有良好的响应。引文:研讨会,ASHRAE交易,第95卷,pt。1989年,芝加哥
An empirical model of a chilled water coil was developed with the technique of system identification. The coil model was used to develop a simulation of a direct digital controller to predict the system response to inputs with P, PI, and PID control algorithms. The response of an actual chilled water coil was measured and compared to the predicted response for the model The model was found to be effective in predicting the response for different values of gain for each type of control algorithm. When the model was used, a set of gains was found that gave a favorable response for the system.
分类信息
发布单位或类别: 未知国家-其他未分类
关联关系
研制信息
相似标准/计划/法规
现行
RP-1194
Dynamic Modeling of Chilled Water Cooling Coils
冷冻水冷却盘管的动态建模
现行
KA-2141
Dynamic Study of a Chill Water Cooling and Dehumidifying Coil
冷水冷却除湿盘管的动态研究
现行
HO-2684
Effective Chilled-Water Coil Control to Reduce Pump Energy and Flow Demand
有效的冷冻水盘管控制 降低泵的能量和流量需求
现行
SE-99-09-3
Dynamics of Primary/Secondary Chilled Water Systems
一次/二次冷冻水系统的动力学
现行
SA-12-001
Simulations of Chilled Water Cooling Coil Delta-T Characteristics
冷冻水冷却盘管Delta-T特性的模拟
现行
LO-09-064
Experimental Measurement and Uncertainty Analysis on the Energy Performance of a Chilled Water Cooling Coil
冷水盘管能量性能的实验测量及不确定度分析
现行
DA-76-07-3
Central Chilled Plant Supply and Return Main Differential Pressure Control of Chilled Water
中央冷冻设备冷冻水供应和回流主压差控制
现行
DA-76-07-2
Operating Experience with Return Temperature Control of Chilled Water
冷冻水回水温度控制的操作经验
现行
AT-19-C045
Effect of the Specification of Chilled and Hot Water Coil on Efficiency of Air Conditioning System with Water Thermal Storage
冷热盘管规格对水蓄冷空调系统效率的影响
现行
CH-89-06-6
Applications of Optimal Control to Chilled Water Systems without Storage
最优控制在无蓄冷系统中的应用
现行
SL-90-13-3
Near-Optimal Control of Cooling Towers for Chilled Water Systems
冷冻水系统冷却塔的近似最优控制
现行
CH-85-16-3
Development of Computerized Control Strategies for a Large Chilled Water Plant
大型冷水厂计算机控制策略的开发
现行
CH-89-06-5(RP-539)
Methodologies for Optimal Control of Chilled Water Systems Without Storage
无储存冷冻水系统的最优控制方法
现行
NY-91-11-2
Control of Variable-Speed Pumps on Hot- and Chilled-Water Systems
热水和冷水系统中变速泵的控制
现行
DV-80-03-3
Control of a Heat Pump/Storage/Solar Hot Water-Chilled Water Central Plant
热泵/蓄热/太阳能热水-冷冻水集中装置的控制
现行
NY-14-020
Optimal Design and Control of Ice Thermal Storage System for a Typical Chilled Water Plant
典型冷水厂冰蓄冷系统的优化设计与控制
现行
AT-15-C005
Exergy Analysis of Chilled-Water Circuit under Different Variable-Flow Control Methods and Supply Water Temperatures
不同变流量控制方式和供水温度下冷冻水回路的火用分析
现行
NY-14-C077
Primary Chilled Water System Control Optimization Integrated with Secondary System Linearization, Part 2: Field Investigation
一次冷冻水系统控制优化与二次系统线性化相结合 第2部分:现场调查
现行
RP-143
Design Procedures and Selection Guide for Hot Water Coils to Attain a Well Controlled System
实现良好控制系统的热水盘管设计程序和选择指南
现行
NY-14-C076
Primary Chilled Water System Control Optimization Integrated with Secondary System Linearization, Part 1: Theoretical Analysis and Simulation
一次冷冻水系统控制优化与二次系统线性化相结合 第1部分:理论分析与仿真