Acoustics. Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms-Application to Type B elements when the junction has a small influence
声学相邻房间之间空气、撞击和建筑服务设备声音侧翼传输的实验室和现场测量
BS EN ISO 10848-2:2017 specifies measurement methods to characterize the flanking transmission of one
or several building components. This document considers only laboratory measurements.The measured quantities can be used to compare different products, or to express a requirement, or
as input data for prediction methods, such as ISO 12354-1 and ISO 12354-2. However, the measured
quantities Dn,f, Ln,f and Lne0,f only represent the performance with the dimensions for the test specimens
described in this document.This document is referred to in ISO 10848-1:2017, 4.5 as being a supporting part of the frame document.
It applies to Type B elements as defined in ISO 10848-1, such as suspended ceilings, access floors,
light uninterrupted facades or floating floors. The transmission from one room to another can occur
simultaneously through the test element and via the plenum (if any). For measurements made according
to this document, the total sound transmission is determined and it is not possible to separate the two
kinds of transmission.Cross References:ISO 354:2003 (R05) Ed 2ISO 10848-1:2017ISO 717-2:2013 ED3ISO 717-1:2013 ED3ISO 12999-1:2014ISO 12354-1:2017ISO 15186-1:2000ISO 12354-2:2017ISO 10140-2:2010ISO 10140-3:2010All current amendments available at time of purchase are included with the purchase of this document.