1.1
These test methods cover the energy consumption and cooking performance of range tops. The food service operator can use this evaluation to select a range top and understand its energy consumption.
1.2
These test methods are applicable to gas and electric range tops including both discreet burners and elements and hot tops.
1.3
The range top can be evaluated with respect to the following (where applicable):
1.3.1
Energy input rate (see
10.2
), and
1.3.2
Pilot energy consumption (see
10.3
).
1.3.3
Heat-up temperature response and temperature uniformity at minimum and maximum control settings (see
10.4
),
1.3.4
Cooking energy efficiency and production capacity (see
10.5
), and
1.3.5
Simmer energy consumption rate (optional, see
10.6
).
1.4
The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
====== Significance And Use ======
5.1
The energy input rate test is used to confirm that the range top under test is operating at the manufacturer's rated input. This test would also indicate any problems with the electric power supply or gas service pressure.
5.2
The heat transfer characteristics of a cooking unit can be simulated by measuring the temperature uniformity of a steel plate.
5.3
Idle energy rate and pilot energy consumption can be used by food service operators to estimate energy consumption during non-cooking periods.
5.4
The heat-up energy efficiency is a direct measurement of range top efficiency at the full-energy input rate and simmer energy is a measurement of the range top efficiency while maintaining operational temperature. This data can be used by food service operators in the selection of range tops, as well as for the management of a restaurant’s energy demands.
Note 1:
The PG&E Food Service Technology Center has determined that the cooking energy efficiency does not significantly change for different input rates. If precise efficiency calculations are desired at lower input rates, the full-input rate test procedure is valid for all input rates (that is, less than full-input).
5.5
Production rate and production capacity can be used to estimate the amount of time required for food preparation and as a measure of range top capacity. This helps the food service operator match a range top to particular food output requirements.