首页 馆藏资源 舆情信息 标准服务 科研活动 关于我们
现行 BN-97-01-2
到馆提醒
收藏跟踪
购买正版
Demand Controlled Ventilation of an Entertainment Club 娱乐俱乐部的按需控制通风
指出娱乐俱乐部、夜总会、剧院和餐厅的占用率变化很大,是需求控制通风的最佳选择。通过控制室外空气的通风以满足加热、冷却和湿度要求,以及保持可接受的室内空气质量,可以实现显著的节能。描述了安装在爱达荷州博伊西一家娱乐俱乐部的按需控制通风系统,该系统使用对挥发性有机化合物敏感的多气体室内空气质量传感器来测量室内空气污染物的水平,当与混合空气温度传感器结合以提供节能器冷却时,该传感器以充分通风空间所需的速率引入室外空气。单位:双关键词:1997年,通风,控制,娱乐空间,美国,案例研究,传感器,二氧化碳,有机化合物,性能,需求控制通风: 研讨会,ASHRAE交易,第103卷,第2部分,波士顿1997年
Points out that entertainment clubs, nightclubs, theatres and restaurants, with their highly variable occupation rate, are excellent candidates for demand controlled ventilation. Significant energy savings may be realised by controlling the ventilation of outdoor air to match the heating, cooling and humidity requirements as well as maintaining acceptable indoor air quality. Describes a demand controlled ventilation system installed in an entertainment club in Boise, Idaho, using a multigas indoor air quality sensor sensitive to volatile organic compounds to measure the level of indoor air pollutants which, when combined with a mixed-air temperature sensor to provide economiser cooling, introduces outdoor air at a rate required to adequately ventilate the space.Units: DualKEYWORDS: year 1997, Ventilation, controls, entertainment spaces, USA, case studies, sensors, carbon dioxide, organic compounds, performance, demand controlled ventilation
分类信息
发布单位或类别: 未知国家-其他未分类
关联关系
研制信息
相似标准/计划/法规
现行
OR-16-C001
Field Performance of Demand Control Ventilation in VAV Systems
变风量空调系统中按需控制通风的现场性能
现行
ML-11-C032
Demand Control Ventilation Methods to Meet ASHRAE Standards
满足ASHRAE标准的需求控制通风方法
现行
NY-14-C009
The First Step of Demand Control Ventilation in an Animal Facility in Japan: Design and Commissioning for Flexible Ventilation
日本动物设施按需控制通风的第一步:灵活通风的设计和调试
现行
RP-1547
CO2-Based Demand Controlled Ventilation for Multiple Zone HVAC Systems
多区域HVAC系统中基于CO2的需求控制通风
现行
LV-11-C062
Demand Control Ventilation: Lessons from the Field- How to Avoid Common Problems
需求控制通风:现场经验教训——如何避免常见问题
现行
LB-07-026
Calibrated Simulation for Retrofit Evaluation of Demand-Controlled Ventilation in Small Commercial Buildings
小型商业建筑按需控制通风改造评估的校准模拟
现行
TO-98-21-1
Application of CO2-Based Demand-Controlled Ventilation Using ASHRAE Standard 62: Optimizing Energy Use and Ventilation
使用ASHRAE标准62的基于CO2的需求控制通风的应用:优化能源使用和通风
现行
IN-91-15-1
Simulated Performance of Demand-Controlled Ventilation Systems Using Carbon Dioxide as an Occupancy Indicator
以二氧化碳为占用指标的按需控制通风系统的模拟性能
现行
SA-12-C038
Supply Air CO2-Based Demand-Controlled Ventilation for Multi-Zone HVAC Systems
多区域HVAC系统中基于供气CO2的按需控制通风
现行
VC-20-004
Feasibility of Low-Cost CO2 Sensors for Demand-Controlled Ventilation--Laboratory Chamber Testing
按需控制通风用低成本CO2传感器的可行性——实验室室内试验
现行
ASTM F2976-13(2023)
Standard Practice for Determining the Field Performance of Commercial Kitchen Demand Control Ventilation Systems
商业厨房按需控制通风系统现场性能测定的标准实施规程
2023-08-01
现行
NY-14-007
Evaluation on the Validity of the Assumptions Underlying CO2-based Demand-controlled Ventilation (RP-1547)
基于二氧化碳的需求控制通风(RP-1547)假设的有效性评估
现行
OR-20-C027
Experimentally Validated CFD Analysis on the Optimal Sensor Location for the CO2-Based Demand-Controlled Ventilation
基于CO2的需求控制通风最佳传感器位置的实验验证CFD分析
现行
CH-15-C035
Use of Demand Control Ventilation on Kitchen Hoods in U.S. Army/Air Force Dining Facilities
在美国陆军/空军餐饮设施的厨房抽油烟机上使用需求控制通风
现行
AT-15-C061
Measured Occupancy Levels in Apartments and the Consequential Simulated Energy Benefit from Demand-Controlled Ventilation
测量的公寓入住率水平以及需求控制通风带来的相应模拟能源效益
现行
AT-19-C068
Simulation Study of Infiltration Effects on Demand Controlled Ventilation System with High-variant Occupancy Schedules
高变化占用率下需求控制通风系统渗透效应的模拟研究
现行
NY-14-C047
Energy Analysis of CO2-Based Demand Controlled Ventilation and Economizer for Air Source Heat Pump in Schools
基于CO2的学校空气源热泵需量控制通风节能器的能量分析
现行
RP-1747
Implementation of RP-1547 CO2-based Demand Controlled Ventilation for Multiple Zone HVAC Systems in Direct Digital Control Systems
直接数字控制系统中多区域HVAC系统基于RP-1547 CO2的按需控制通风的实现
现行
ST-16-C014
Practical Approach and Method of Demand Control Ventilation in an Animal Facility which Achieves 50% HVAC Energy Saving
在动物设施中实现空调节能50%的需求控制通风的实用方法和途径
现行
RP-740
An Evaluation of the Effect of Co2 Based Demand Controlled Ventilation Strategies on Energy Use and Occupant Source Contamination Concentration
基于二氧化碳的需求控制通风策略对能源使用和乘客源污染浓度的影响评估